Operating instructions
ProMinent
®
Page 36
Repair
왘 If the diaphragm rupture sensor opens at every stroke, unscrew it until it remains just open
and then screw on nut
왘 Screw the housing back on (is the O-ring seated correctly beneath?)
왘 Tighten the union nut on the PG threaded connector (must be sealed.)
11.3 Piston liquid end (TZKa)
Disassembling liquid end 왘 Remove the protective cover (4) from the turret (see Fig. 25)
왘 Remove circlip (2) from the bolt on the coupling head and remove bolt (1)
왘 Place a sling around the liquid end and attach to a crane.
WARNING
•A helper should steady the liquid end by hand.
It could slip out of the sling if allowed to swing freely.
• Ensure that the pistons cannot fall out!
왘 (Where applicable: remove leakage or flushing hoses from the hose nozzles (5))
왘 Remove locking screws (3)
왘 Remove the liquid end and place on a firm, level base.
Fig. 25 Diaphragm rupture sensor (*)
Fig. 26
1 Bolt
2 Safety collar
3 Locking screw
4Protective cover
5 Hose nozzles for
leakage/flushing
connector
Servicing liquid end 왘 Unfasten the tensioning screw (3) with the face spanner and remove (see Fig. 26)
왘 Unfasten screws on liquid end flange (4) and remove liquid end flange
왘 Remove piston (1)
IMPORTANT
Make a note of the order in which you remove the parts.
12
4
3
5