Operating instructions
ProMinent
®
Page 45
Technical data
Makro TZ (TZMb) motor data table
Identity Code Supply Remarks
special feature
S3 ph, IP 55 220-240 V/380-420 V 50 Hz 0.75 kW
250-280 V/440-480 V 60 Hz 0.75 kW
L1 3 ph, II2GEEXeIIT3 220-240 V/380-420 V 50 Hz 0.75 kW
L2 3 ph, II2GEEXdIICT4 220-240 V/380-420 V 50 Hz 0.75 kW with PTC thermistor, speed control range 1:5
P1 3 ph, II2GEEXeIIT3 250-280 V/440-480 V 60 Hz 0.75 kW
P2 3 ph, II2GEEXdIICT4 250-280 V/440-480 V 60 Hz 0.75 kW with PTC thermistor, speed control range 1:5
R3 ph, IP 55 230 V/400 V 50/60 Hz 1.5 kW with PTC thermistor, speed control range 1:20
with external fan 1ph 230 V; 50/60 Hz
V0 3 ph, IP 55 400 V ±10 % 50/60 Hz 1.5 kW variable-speed motor with integrated
frequency converter
V2 3 ph, II2GEExdIICT4 400 V ±10 % 50/60 Hz 1.5 kW Ex-variable-speed motor with integrated
frequency converter
Please request motor data sheets for more information.
Special motors and motor flanges are possible on request.
14 Technical data
WARNING
Only for modified version: Please observe the “Supplement for modified version” at the end
of the section!
It replaces and supplements the technical data!
Table of main pumps diaphragm liquid ends (TZMb)
with 1500 rpm motor at 50 Hz with 1800 rpm motor at 60 Hz
Capacity Max. Capacity Stroke Suction Connection Shipping
at max. stroke at max. count at lift suction/ weight
back pressure frequency back pressure max. back discharge PP, PC,
pressure side TT/SS
Pump type bar l/h ml/ strokes/ psi l/h gph strokes/ m WG G-DN kg
TZMbH stroke min min.
120260 12 260 60 72 174 309 81.8 86 5 1 1/2 - 25 46/54
120340 12 340 60 96 174 414 109.5 115 5 1 1/2 - 25 46/54
120430 12 430 60 120 174 518 137 144 5 1 1/2 - 25 46/54
120510 12 510 60 144 174 622 164.5 173 5 1 1/2 - 25 46/54
120650 12 640 60 180 174 – – – 5 1 1/2 - 25 46/54
070430 7 430 99 72 100 511 135 86 4 2 - 32 50/64
070570 7 570 99 96 100 683 180 115 4 2 - 32 50/64
070720 7 720 99 120 100 855 226 144 4 2 - 32 50/64
070860 7 860 99 144 100 1028 272 173 4 2 - 32 50/64
071070 7 1070 99 180 100 – – – 4 2 - 32 50/64
040840 4 840 194 72 58 1001 264 86 3 2 1/4 - 40 56/80
041100 4 1100 194 96 58 1339 354 115 3 2 1/4 - 40 56/80
041400 4 1400 194 120 58 1676 443 144 3 2 1/4 - 40 56/80
041670 4 1670 194 144 58 2014 532 173 3 2 1/4 - 40 56/80
042100 4 2100 194 180 58 – – – 3 2 1/4 - 40 56/80
Material version PPT/PCT/TTT 10 bar max.
The permissible priming pressure on the suction side is approx. 50 % of the max. permissible back pressure.
With dual head pumps, the maximum permissible back pressure is reduced from 7 to 5.5 bar and from 4 to 3 bar
respectively (from 101.5 psi to 80 psi and from 58 psi to 43.5 psi respectively).
All figures apply for water at 20 °C.
The suction lift applies for filled suction line and liquid end - with correct installation.
The priming lift of 2 m applies for clean and wetted valves and free discharge
(the values reduce with valve springs!).
BA_MA_TZ_006_10_06_GB.p65 05.02.2007, 13:41 Uhr45