Technical data
Table of main pumps hydraulic diaphragm liquid ends (TZHa)
with 1500 rpm motor at 50 Hz with 1800 rpm motor at 60 Hz
Capacity Max. Capacity Max. Suction Connection Shipping Hydraulic
at max. stroke at max. stroke lift suction/ weight
back pressure frequency back pressure frequency discharge
side
Pump type bar l/h ml/ strokes/ psi l/h/gph strokes/ m WG G-DN kg* Ø mm
TZHa stroke min. min.
160300 16 300 69.4 72 232 424/112 86 3 1 1/2-25 80 70
160400 16 400 69.4 96 232 480/126 115 3 1 1/2-25 80 70
160500 16 500 69.4 120 232 600/158 144 3 1 1/2-25 80 70
160600 16 600 69.4 144 232 720/190 173 3 1 1/2-25 80 70
160750 16 750 69.4 180 232 – / – 3 1 1/2-25 80 70
100502 10 502 116.2 72 145 602/159 86 3 2 1/4-40 81 90
100669 10 669 116.2 96 145 802/211 115 3 2 1/4-40 81 90
100836 10 836 116.2 120 145 1003/264 144 3 2 1/4-40 81 90
101004 10 1004 116.2 144 145 1204/318 173 3 2 1/4-40 81 90
101204 10 1204 116.2 180 145 – / – 3 2 1/4-40 81 90
Special versions on request
Material version PPE/PCA/TTT 10 bar max.
* stainless steel version 95 kg
The permissible priming pressure on the suction side is approx. 50 % of the max. permissible back pressure.
All figures apply for water at 20 °C.
The suction lift applies for filled suction line and liquid end - with correct installation.
The priming lift of 2 m applies for clean and wetted valves and free discharge (the values reduce with valve springs!).
Makro TZ (TZHa) motor data table
Identity Code Supply Remarks
special feature
S3 ph, IP 55 220-240 V/380-420 V 50 Hz 1.5 kW
250-280 V/440-480 V 60 Hz 1.5 kW
L1 3 ph, II2GEEXeIIT3 220-240 V/380-420 V 50 Hz 1.5 kW
L2 3 ph, II2GEEXdIICT4 220-240 V/380-420 V 50 Hz 1.5 kW with PTC thermistor, speed control range 1:5
P1 3 ph, II2GEEXeIIT3 250-280 V/440-480 V 60 Hz 1.5 kW
P2 3 ph, II2GEEXdIICT4 250-280 V/440-480 V 60 Hz 1.5 kW with PTC thermistor, speed control range 1:5
R3 ph, IP 55 230 V/400 V 50/60 Hz 2.2 kW with PTC thermistor, speed control range 1:20
with external fan 1ph 230 V; 50/60 Hz
V0 3 ph, IP 55 400 V ±10 % 50/60 Hz 2.2 kW variable-speed motor with integrated
frequency converter
V2 3 ph, II2GEExdIICT4 400 V ±10 % 50/60 Hz 2.2 kW Ex-variable-speed motor with integrated
frequency converter
Please request motor data sheets for more information.
Table of main pumps piston liquid ends (TZKa)
with 1500 rpm motor at 50 Hz with 1800 rpm motor at 60 Hz
Capacity Max. Capacity Max. Suction Connection Shipping Hydraulic
at max. stroke at max. stroke lift suction/ weight
back pressure frequency back pressure frequency discharge
side
Pump type bar l/h ml/ strokes/ psi l/h/gph strokes/ m WG G-DN kg* Ø mm
TZKa stroke min. min.
320009 320 8.7 2 72 4627 10/ 2.6 86 4 Rp 1/4**- 8 50 12
320012 320 11.6 2 96 4627 14/ 3.7 115 4 Rp 1/4**- 8 50 12
320014 320 14.5 2 120 4627 17/ 4.5 144 4 Rp 1/4**- 8 50 12
320017 320 17.4 2 144 4627 21/ 5.5 173 4 Rp 1/4**- 8 50 12
320018 320 17.7 4.1 72 4627 21/ 5.5 86 4 Rp 1/4**- 8 50 17
320024 320 23.6 4.1 96 4627 28/ 7.4 115 4 Rp 1/4**- 8 54 17
320030 320 29.5 4.1 120 4627 35/ 9.2 144 4 Rp 1/4**- 8 54 17
313035 313 35.4 4.1 144 4526 42/ 11 173 4 Rp 1/4**- 8 54 17