Technical data
192033 192 32.9 7.6 72 2776 39/ 10 86 4 Rp 3/8**- 10 55 23
192044 192 43.9 7.6 96 2776 59/ 14 115 4 Rp 3/8**- 10 55 23
192055 192 54.8 7.6 120 2776 66/ 17 144 4 Rp 3/8**- 10 55 23
168066 168 65.8 7.6 144 2437 79/ 20 173 4 Rp 3/8**- 10 55 23
113057 113 57.5 13.3 72 1634 69/ 18 86 4 Rp 3/8**- 10 56 30
113077 113 76.6 13.3 96 1634 92/ 24 115 4 Rp 3/8**- 10 56 30
113096 113 95.8 13.3 120 1634 115/ 30 144 4 Rp 3/8**- 10 56 30
096115 96 114.9 13.3 144 1392 138/ 36 173 4 Rp 3/8**- 10 56 30
063104 63 104.3 24.2 72 911 125/ 33 86 4 1 1/4- 20 58 40
063139 63 139 24.2 96 911 167/ 44 115 4 1 1/4- 20 58 40
063174 63 173.8 24.2 120 914 209/ 55 144 4 1 1/4- 20 58 40
052208 52 208.5 24.2 144 754 250/ 66 173 4 1 1/4- 20 58 40
040163 40 162.9 37.7 72 578 195/ 51 86 4 1 1/4- 20 58 50
040217 40 217.2 37.7 96 578 261/ 68 115 4 1 1/4- 20 58 50
040271 40 271.5 37.7 120 580 326/ 86 144 4 1 1/4- 20 58 50
033326 33 325.8 37.7 144 479 391/103 173 4 1 1/4- 20 58 50
028237 28 237 54.9 72 405 284/ 75 86 4 1 1/2- 25 62 60
028316 28 315.9 54.9 96 405 379/100 115 4 1 1/2- 25 62 60
027395 27 394.9 54.9 120 392 474/125 144 4 1 1/2- 25 62 60
022474 22 473.9 54.9 144 319 569/150 173 4 1 1/2- 25 62 60
020322 20 322.5 74.7 72 289 387/102 86 4 1 1/2- 25 62 70
020430 20 430 74.7 96 289 516/136 115 4 1 1/2- 25 62 70
020538 20 537.6 74.7 120 290 645/170 144 4 1 1/2- 25 62 70
016645 16 645.1 74.7 144 232 774/204 173 4 1 1/2- 25 62 70
014475 14 475.1 110 72 202 571/150 86 4 2 1/4- 40 68 85
014634 14 634.1 110 96 202 761/201 115 4 2 1/4- 40 68 85
013793 13 792.6 110 120 189 951/251 144 4 2 1/4- 40 68 85
011951 11 951.1 110 144 160 1141/301 173 4 2 1/4- 40 68 85
** The Rp 1/4 and Rp 3/8 suction and discharge side connections have female threaded connections and are constructed as
double ball valves.
The permissible priming pressure on the suction side is approx. 50 % of the max. permissible back pressure.
ll figures apply for water at 20 °C.
The suction lift applies for filled suction line and liquid end - with correct installation.
The priming lift of 2 m applies for clean and wetted valves and free discharge(the values reduce with valve springs!).
with 1500 rpm motor at 50 Hz with 1800 rpm motor at 60 Hz
Capacity Max. Capacity Max. Suction Connection Shipping Hydraulic
at max. stroke at max. stroke lift suction/ weight
back pressure frequency back pressure frequency discharge
side
Pump type bar l/h ml/ strokes/ psi l/h/gph strokes/ m WG G-DN kg* Ø mm
TZKa stroke min. min.
Makro TZ (TZKa) motor data table
Identity Code Supply Remarks
special feature
S3 ph, IP 55 220-240 V/380-420 V 50 Hz 1.5 kW
250-280 V/440-480 V 60 Hz 1.5 kW
L1 3 ph, II2GEEXeIIT3 220-240 V/380-420 V 50 Hz 1.5 kW
L2 3 ph, II2GEEXdIICT4 220-240 V/380-420 V 50 Hz 1.5 kW with PTC thermistor, speed control range 1:5
P1 3 ph, II2GEEXeIIT3 250-280 V/440-480 V 60 Hz 1.5 kW
P2 3 ph, II2GEEXdIICT4 250-280 V/440-480 V 60 Hz 1.5 kW with PTC thermistor, speed control range 1:5
R3 ph, IP 55 230 V/400 V 50/60 Hz 2.2 kW with PTC thermistor, speed control range 1:20
with external fan 1ph 230 V; 50/60 Hz
V0 3 ph, IP 55 400 V ±10 % 50/60 Hz 2.2 kW variable-speed motor with integrated
frequency converter
V2 3 ph, II2GEExdIICT4 400 V ±10 % 50/60 Hz 2.2 kW Ex-variable-speed motor with integrated
frequency converter
Please request motor data sheets for more information.
BA_MA_TZ_006_10_06_GB.p65 05.02.2007, 13:41 Uhr48