Operating instructions

ProMinent
®
Page 5
Identcode
Identcode
Please transfer the identity code listed under “Type” on the rating plate into the frame below
*order-related version,
refer to purchase
order paperwork for
pump characteristics
TZMa Makro TZ 6/9 Diaphragm Metering Pump
Drive type:
H Main drive
A Add-on drive
D Main drive double
B Add-on drive double
Pump type: (digits 1 + 2 = back pressure, digits 3-6 = capacity [l/h
120190 060397 031875
120254 060529 031050
120317 060661 031395
120381 060793 031740
030750 032100
031000 032500
031250
031500 Material version PCA/PPE/TTT 10 bar max.
Liquid end material
PC PVC
PP Polypropylene
SS Stainless steel
TT PTFE + 25% carbon
Seals material
A FPM
E EPDM
T PTFE
Positive displacement material
T Standard diaphragm: PTFE version
Liquid end version
0 Without valve spring
1 With valve spring
Hydraulic connection
0 Standard connection
1 Union nut and insert PVC
2 Union nut and insert PP
3 Union nut and insert PVDF
4 Union nut and insert SS
Version
0 With ProMinent
®
logo
2 Without ProMinent
®
logo
A With ProMinent
®
logo, with frame, single
B With ProMinent
®
logo, with frame, double
C With ProMinent
®
logo, with frame, triple
M Modified*
Electrical supply
S3 ph. 230/400 V 50/60 Hz (multi-voltage)
P3 ph. 265/460 V 60 Hz (Exe, Exde)
L3 ph. 230/400 V 50/60 Hz (Exe, Exde)
R3 ph. 4 pole speed-controlled motor 230/400 V
V3 ph. pole speed-controlled motor with integral FC
Z Speed control system, complete
4 Without motor, with flange 56 C
7 Without motor, with flange 120/80
8 Without motor, with flange 160/90
9 Without motor, with flange 200/90
Protection class
0 IP 55 (standard) ISO Class F
1 Exe version ATEX-T3
2 Exde version ATEX-T4
AATEX drive
Stroke sensor
0 Without stroke sensor
1 With stroke sensor (Namur)
Stroke length adjustment
0 Manual stroke length adjustment
1 Actuator 230 V
2 Actuator 115 V
3 Positioning motor 230V 0 -20 mA
4 Positioning motor 230 V 4-20 mA
5 Positioning motor 115 V 0-20 mA
6 Positioning motor 115 V 4-20 mA
Application
0 Standard
TZMa
–– –– –– –– –– –– –– –– –– –– –– –– –– ––
FPM = Fluorine rubber
BA_MA_TZ_006_10_06_GB.p65 05.02.2007, 13:41 Uhr5