Chapter 8: Troubleshooting
313
Firmware version
To view this information in WebPAM PROe, click the Controller icon,
Information tab.
6. Shut down the VTrak.
7. Remove the first controller and install the second controller.
8. Repeat steps 3 through 6.
9. Compare your records.
10. Correct any differences between the two controllers.
Taking a Controller out of Maintenance Mode
If you shut down the VTrak in the process of correcting the problem, the controller
boots into normal mode when the VTrak restarts. No further action is required.
If you corrected the problem without shutting down the VTrak, choose one of the
following methods to take the controller out of maintenance mode:
Reboot the VTrak
Establish a serial connection, then use the CLI (see below)
Establish a Telnet connection, then use the CLI (see page 314)
Serial Connection
To clear maintenance mode using a serial connection:
1. Change your terminal emulation program settings to match the following
specifications:
Bits per second: 115200
Data bits: 8
Parity: None
Stop bits: 1
Flow control: none
2. Start your PC’s terminal VT100 or ANSI emulation program.
3. Press Enter once to launch the CLI.
The login screen appears.
The following steps show the default Administrator user name and
password. Use your own user name and password if you have changed
these.
4. At the Login prompt, type administrator and press Enter.
5. At the Password prompt, type password and press Enter.
The CLI screen appears.