Product manual

VTrak E-Class Product Manual
328
Reported Event Corrective Action
Battery
Battery is inserted No action is required.
Battery charging has failed Replace the battery.
Battery reconditioning has started No action is required.
Battery reconditioning has been
terminated
Replace the battery.
The write policy of writeback logical
drive switched from writeback to
writethru
Check the event log to see whether
battery is re-conditioning.
The write policy of writeback logical
drive switched from writethru to
writeback
No action is required.
Battery is charging in high temperature Monitor the condition. Contact Tech
Support if the problem persists.
Battery cannot function with the
enclosure or with the attached battery
board
Wrong battery installed. Contact Tech
Support for assistance.
Logical drive writeback cache maybe
enabled without battery support
No action required.
Battery is fully charged
Battery is not present Install a battery or verify that the battery
is properly connected.
Battery is not accessible Connect the battery properly or replace
the battery.
BBU
BBU flushing has started
No action is required.
BBU flushing has ended
BBU flushing has failed Contact Tech Support if the condition
persists.
Blade Server
Blade Server Inserted
No action is required.
Blade Server Removed
Cache
Not available Contact Tech Support.