Product manual

VTrak E-Class Product Manual
330
Controller is started
No action is required.Controller is set to Active Mode
Controller is set to Standby Mode
Controller Failed Over as partner is
removed
Verify that the partner controller is
properly installed and all cables are
connected.
Controller Failed Over as heart beat
stopped
Controller Firmware mismatch with that
of the partner controller
Auto Firmware synchronization
upgrades or downgrades the firmware.
Controller set to Maintenance Mode
because of hardware mismatch with
partner (controller)
Compare controller types and amount
of memory installed. Correct or update
as needed.
Controller set to Maintenance Mode
because of firmware mismatch with
partner controller
Update this controller to the same
firmware version as the partner
controller.
Controller set to Maintenance Mode
because Firmware is flashing in the
partner controller
Exit out of Maintenance mode after
firmware flashing is complete.
Controller set to Maintenance Mode
because of flash image version
mismatch with partner (controller)
Update this controller to the same flash
image version as the partner controller.
Controller has been set to Maintenance
mode because there is a mismatch in
the Controller Model or Hardware
version with that of the partner
controller
Replace this controller with the same
Model and Hardware version as the
partner controller.
Controller has been set to Maintenance
mode because there is a mismatch in
the memory size with that of the partner
controller
Replace this controller’s memory with
the same memory size as the partner
controller
Partner Controller has entered
maintenance mode to protect user data
since one of the configured physical
drives was disconnected in the partner
controller
Check and correct cable connections to
external JBOD enclosures. Rebuild any
critical logical drives. Back up array
data. Replace the physical drive. Bring
controller out of maintenance mode.
Reported Event Corrective Action