Product manual

Chapter 8: Troubleshooting
341
Migration has cleared stale NV
Watermark
No action is required.
Array was made incomplete due to
missing NV Watermark
If the array is online, try migration
again. If the array is offline, delete and
recreate the array.
User has accepted Incomplete Array.
(Caused by a missing NV Watermark)
Rebuild the disk array.
Rebuild
Rebuild is started
No action is required.Rebuild is in progress
Rebuild is completed
Rebuild is paused Resume rebuild when ready.
Rebuild is resumed No action is required.
Rebuild is stopped If this action was not intentional, check
the logical drive’s status.
Rebuild stopped internally Contact Tech Support.
Rebuild is aborted Reduce system load on the VTrak.
Rebuild is queued No action is required.
Auto rebuild cannot start Install a target physical drive of
adequate capacity.
Redundancy Check
Redundancy Check is started
No action is required.
Redundancy Check is completed
Redundancy Check is paused Resume Redundancy Check when
ready.
Redundancy Check is resumed
No action is required.
Redundancy Check is stopped
Redundancy Check is aborted due to
internal error
Reduce system load on the VTrak.
Redundancy Check encountered
inconsistent block(s)
Check the disk drive check table after
RC and replace disk drive as needed.
Redundancy Check task is queued
No action is required.
Redundancy check is in progress
Reported Event Corrective Action