User manual
Promise Array Manager 
62 
Disk Parameters: SMART Check 
SMART, an acronym for Self-Monitoring Analysis and Reporting Technology, 
is a feature of the disk drive software. It monitors the internal performance of 
the drive and reports to the PC when it finds a potential failure. SMART 
warns you of a developing drive failure so you can replace the drive before it 
actually fails. 
Rebuild Options: Disable Hot Spare/Auto Rebuild 
For mirrored arrays (RAID 1 and 0+1), this option turns off the hot spare 
drive and automatic rebuilding. The default is unchecked, hot spare and 
automatic rebuilding enabled. 
Rebuild Options: Rebuild Rate 
A High setting assigns most of the system resources to rebuilding. 
Rebuilding goes faster, restoring redundancy sooner but read/write requests 
are handled slower. 
A Low setting assigns most of the system resources to handling read/write 
requests. Read/write requests are handled at nearly normal speed while the 
rebuild takes longer. 
See Rebuild an Array later in this chapter for more information on the 
rebuilding process. 
PCI Bus Utilization 
On High setting, FastTrak holds onto the PCI bus longer for data transfers to 
occur. 
On Low setting, FastTrak releases the PCI bus sooner for other PCI devices 
to use. 
Normally, no adjustment is required. However, some video capture cards 
may produce a glitch during playback of audio/video files. If this happens, try 
adjusting the slider. 
If any of these features are grayed out, it means they are not available on 
your hard drives. 










