Computer Hardware User Manual

Chapter 8: Troubleshooting
215
The controller has new
crash information
Check the event logs. See page 49.
Controller temperature is
above the threshold/
warning threshold
The VTrak controller is overheating. Check for airflow
around and through the controller, and verify that all
fans are working. Replace fans as needed.
Controller temperature is
above the critical
threshold
The VTrak controller is seriously overheating. Check
for airflow around and through the controller, and
verify that all fans are working. Replace fans as
needed.
Disk Array
New disk array has been
created
Result of settings or user action. Normal.
Disk array has been
deleted
Result of settings or user action. Normal.
Disk array has been
added
Result of settings or user action. Normal.
Disk array has been
removed
The physical drives of the disk array were removed
from the enclosure.
Disk array settings have
been changed
The user successfully logical drive settings. See
page 98.
Drive Interface Controller
Drive-interface controller
found
Normal.
Drive-interface controller
is NOT found
Restart the VTrak. See page 169. If this message
appears repeatedly, contact Technical Support. See
page 239.
Drive-interface
diagnostics has passed
Normal.
Drive-interface
diagnostics has failed
Restart the VTrak. See page 169. If this message
appears repeatedly, contact Technical Support. See
page 239.
Drive-interface controller
has generated a general/
data parity error.
Drive-to-controller parity error. If this message
appears repeatedly, contact Technical Support. See
page 239.
Event Action