User guide
Alert report messages and actions 
WebPAM PRO supports a feature that notifies of alert messages in the ESMPRO/ 
ServerManager when a failure occurs in the EX4650 Disk array controller, by using the event 
logging notification function of ESMPRO/ServerManager and ServerAgent. You can check the 
alert messages that are set for notification in the AlertViewer. The ESMPRO disk array 
monitoring functions (the color indication that changes the color of the server image on the 
ESMPRO/ServerManager operation window and the disk array information displayed on the 
DataViewer) are also supported. The following list shows the messages that are notified by 
WebPAM PRO. 
Just after the installation of WebPAM PRO, the following messages registered with a source 
name "Promise Event Logger" in the application event log are set as the reported sources. To 
change the setting, redefine it by using the report setting feature of the NEC ESMPRO Agent. 
Event 
ID 
Message Action 
512 
Battery temperature is above 
the threshold 
No action required if the ID 517 message has been 
registered within the last 8 hours.   
If there is no ID 517 message, replace the battery. 
517 
Battery is charging 
Helps checking the ID 512 message. 
529 
The write policy of writeback 
logical drive switched from 
writeback to writethru 
Check the battery for any failure. 
530 
The write policy of writeback 
logical drive switched from 
writethru to writeback 
Check the battery for any failure. 
4102 
Logical Drive Initialization is 
aborted due to an internal 
error 
Check the HDD and cables and replace it if any failure 
exists. 
4109 
Quick Logical Drive 
Initialization is aborted due to 
an internal error 
Check the HDD and cables and replace it if any failure 
exists. 
5638 
Media Patrol is aborted due to 
an internal error 
Check the HDD and cables and replace it if any failure 
exists. 
6659 
Physical Disk has been reset 
Check the HDD and cables and replace it if any failure 
exists. 
6667 
Physical Disk has been 
removed 
A Physical drive has been removed. Check the HDDs and 
cables and replace if any failure exists. 
6671 
Bad sector is found on 
physical disk 
Replace the HDD on which bad sectors are detected. 
6149 
RAID migration has 
encountered a physical disk 
error 
A Physical disk error was detected. If it cannot be fixed, 
replace the HDD. 
6150 
RAID migration has 
encountered a physical disk 
error 
Migration aborted. Please contact your sales representative 
for the reconstruction of the array. 
6154 
Array was made Incomplete 
due to missing NV Watermark 
An error occurred during the Migration. Please contact 
your sales representative for the reconstruction of the array. 
7681 
Rebuild is completed 
The Rebuild is completed. Check the status of the logical 
drive. 
7682 
Rebuild is paused 
The Rebuild is stopped. Restart rebuilding as soon as 
possible. 
7683 
Rebuild is resumed 
- 83 - 