Viewing Enclosure Information (CLU)
To view enclosure information:
1.
Main Menu >> Subsystem Management >> Enclosure Management
2. Highlight the enclosure you want and press Enter.
You can monitor power supplies, cooling units, enclosure temperatures and voltages.
Adjustable items
You can set or adjust the following items:
Enclosure Warning and Critical temperature thresholds
See “Making Enclosure Settings” below.
Maki ng Enclosure Settings (CLU)
To make Enclosure settings:
1.
Main Menu >> Subsystem Management >> Enclosure Management
2. Highlight the enclosure you want and press Enter.
3. Highlight
Enclosure Settings and press Enter.
4. Highlight the
Temperature Warning threshold you want to change.
5. Press the backspace key to erase the current value.
6. Type a new interval value in degrees C.
7. Press
Control-A to save your settings.
118
Vess A2000 Series Product Manual