Product manual
VessRAID 1000s Series Product Manual
282
Logical drive initialization 
has stopped
Initialization stopped because of user intervention, 
schedule or the logical drive was deleted or went 
critical or offline.
Logical drive initialization 
marks the logical drive 
offline
Initialization failure due to a failed disk drive. Replace 
the disk drive, delete and recreate the logical drive. 
See page 105 (WebPAM PROe) or page 148 (CLU).
Logical drive initialization 
is aborted due to an 
internal error.
System resources are low. Reduce system load or 
restart the VessRAID. See page 85 (WebPAM PROe) 
or page 191 (CLU).
Logical drive initialization 
is queued
Initialization has been set manually or by schedule.
A new logical drive has 
been created
Result of user action. Normal.
Logical drive has been 
deleted
Result of user action. Normal.
Logical drive has been 
placed online
The physical drives of the array are restored to online 
status.
Logical drive has been 
placed online. Possible 
data loss
One or more physical drives in the array went offline. 
See page 290.
Logical drive has been set 
to critical.
One or more physical drives in the array went offline. 
See page 290.
Logical drive axle has 
been placed online
RAID 50 and 60. One of the axles (RAID 5 or 6 
arrays) returned on online status.
Media Patrol
Media patrol is started Result of settings or user action. Normal.
Media patrol is completed Normal.
Media patrol is paused Media patrol paused because of user intervention, 
schedule or a higher priority background activity.
Media patrol is resumed Media patrol has resumed again after a pause.
Media patrol is stopped Media patrol stopped because of user intervention, 
schedule or the logical drive was deleted or went 
critical or offline.
Media patrol is aborted 
due to an internal error.
System resources are low. Reduce system load or 
restart the VessRAID. See page 85 (WebPAM PROe) 
or page 191 (CLU).
Reported Event Corrective Action