Product manual
VessRAID 1000f, 1000i, 1000s Series Product Manual
382
Battery is discharging Battery is undergoing reconditioning.
Battery is charging Battery is being recharged.
Battery reconditioning is 
complete
Battery reconditioning is finished.
Battery is malfunctioning Run battery reconditioning. Run battery 
reconditioning. See page 143 (WebPAM PROe) or 
page 224 (CLU). If this message reappears, replace 
the battery.
Battery reconditioned 
successfully
Battery reconditioning is finished.
Battery reconditioning has 
failed
Replace the battery. See page 324
Battery is reaching end of 
life
Replace the battery. See page 324.
Battery is removed The battery was disconnected or removed. Reinstall 
the battery. See page 324
Battery charging failed Replace the battery. See page 324.
Battery reconditioning 
started
Battery reconditioning has begun.
Battery recondition 
terminated
The battery was disconnected or removed during 
reconditioning. Reinstall the battery. See page 324.
Blowers
Blowers have started Normal.
Blowers have stopped Verify that the fans are properly installed. If they still 
does not turn, replace the fan. See page 321.
Blower speed is 
increased
Check the VessRAID for overheating. See page 400.
Blower speed is 
decreased
Temporary overheat condition was corrected.
Blowers are NOT 
functioning
Replace the fans. See page 321.
Blowers have been 
inserted
Normal.
Blowers have been 
removed
Reinstall the fan. If the fan does not turn, replace it. 
See page 321.
Reported Event Corrective Action