Product manual
Chapter 10: Troubleshooting
383
Blowers are functioning 
normally
Normal.
Blowers are NOT installed Reinstall the fan. If the fan does not turn, replace it. 
See page 321.
Blower status is unknown Check for airflow out of the cooling unit. If there is 
none, check for proper installation.
Cache
BBU flushing has started VessRAID’s cache is being flushed.
BBU flushing has ended VessRAID’s cache has been flushed.
BBU flushing has failed VessRAID’s cache could not be flushed. Check your 
cache flush interval setting. See page 136 (WebPAM 
PROe) or page 217 (CLU).
Controller
The controller 
parameter(s) changed by 
user
The user successfully changed controller settings. 
See page 136 (WebPAM PROe) or page 217 (CLU).
The controller has new 
crash information
Check the event logs. See page 69 and 70 (WebPAM 
PROe) or page 266 (CLU)
Controller temperature is 
above the threshold/
warning threshold
The VessRAID controller is overheating. Check for 
airflow around and through the controller, and verify 
that all fans are working. Replace fans as needed.
Controller temperature is 
above the critical 
threshold
The VessRAID controller is seriously overheating. 
Check for airflow around and through the controller, 
and verify that all fans are working. Replace fans as 
needed.
Disk Array
New disk array has been 
created
Result of settings or user action. Normal.
Disk array has been 
deleted
Result of settings or user action. Normal.
Disk array has been 
added
Result of settings or user action. Normal.
Disk array has been 
removed
The physical drives of the disk array were removed 
from the enclosure.
Disk array settings have 
been changed
The user successfully disk array settings. See 
page 160 (WebPAM PROe) or page 235 (CLU).
Reported Event Corrective Action