Product manual
Chapter 10: Troubleshooting
393
Synchronization is 
stopped
Synchronization stopped because of user 
intervention, schedule or the logical drive was deleted 
or went critical or offline.
Synchronization is 
aborted due to an internal 
error.
System resources are low. Reduce system load or 
restart the VessRAID. See page 134 (WebPAM 
PROe) or page 288 (CLU).
Synchronization is 
queued
Synchronization is already running on another logical 
drive in the same array.
Synchronization is 
stopped internally
Synchronization stopped because the disk array was 
deleted or removed.
System (VessRAID)
The system is started The VessRAID has been started.
The system is stopped The VessRAID was shut down.
Transition
Transition is started Result of settings or user action. Normal.
Transition is completed Normal.
Transition is paused Transition paused because of user intervention, 
schedule or a higher priority background activity.
Transition is resumed Transition has resumed again after a pause.
Transition is stopped Transition stopped because of user intervention or 
the logical drive was deleted.
Transition was switched 
to rebuild
Transition changed to rebuild because the logical 
drive went critical.
Watermark
Migration has detected/
cleared stale NV 
Watermark
Watermarks are progress markers left as the result of 
interrupted RAID migrations. If the watermark was 
cleared, migration should finish.
Array was incomplete due 
to missing NV Watermark
RAID migration was interrupted by a shutdown. 
If array is online, try migration again. See page 162 
(WebPAM PROe) or page 237 (CLU). 
If array is offline, delete and recreate array. See 
page 158 and page 153 (WebPAM PROe) or 
page 234 and page 230 (CLU).
Reported Event Corrective Action