VTRAK M-CLASS Product Manual

VTrak M-Class Product Manual
272
Battery is charging Battery is being recharged.
Battery reconditioning is
complete
Battery reconditioning is finished.
Battery is malfunctioning Run battery reconditioning. See page 121. If this
message reappears, replace the battery.
Battery reconditioned
successfully
Battery reconditioning is finished.
Battery reconditioning has
failed
Replace the battery. See page 230or page 233.
Battery is reaching end of
life
Replace the battery. See page 230or page 233.
Battery is removed The battery was disconnected or removed. Reinstall
the battery. See page 230or page 233.
Battery charging failed Replace the battery. See page 230or page 233.
Battery reconditioning
started
Battery reconditioning has begun.
Battery recondition
terminated
The battery was disconnected or removed during
reconditioning. Reinstall the battery. See page 230or
page 233.
Blowers
Blowers have started Normal.
Blowers have stopped Verify that the cooling unit is properly installed. If the
blower still does not turn, replace the blowers. See
page 221 or page 226.
Blower speed is
increased
Check the VTrak for overheating. See page 289.
Blower speed is
decreased
Temporary overheat condition was corrected.
Blowers are NOT
functioning
Replace the blowers. See page 221 or page 226.
Blowers have been
inserted
Normal.
Blowers have been
removed
Reinstall the cooling unit(s). If the blowers does not
turn, replace the blowers. See page 221 or page 226.
Blowers are functioning
normally
Normal.
Event Action