Chapter 8: Troubleshooting
273
Blowers are NOT installed Reinstall the cooling unit(s). If the blowers does not
turn, replace the blowers. See page 221 or page 226.
Blower status is unknown Check for airflow out of the cooling unit. If there is
none, check for proper installation.
Cache
BBU flushing has started VTrak’s cache is being flushed.
BBU flushing has ended VTrak’s cache has been flushed.
BBU flushing has failed VTrak’s cache could not be flush. Check your cache
flush interval setting. See page 116.
Controller
The controller
parameter(s) changed by
user
The user successfully change controller settings. See
page 116.
The controller has new
crash information
Check the event logs. See page 70.
Controller temperature is
above the threshold/
warning threshold
The VTrak controller is overheating. Check for airflow
around and through the controller, and verify that all
fans are working. Replace fans as needed.
Controller temperature is
above the critical
threshold
The VTrak controller is seriously overheating. Check
for airflow around and through the controller, and
verify that all fans are working. Replace fans as
needed.
Disk Array
New disk array has been
created
Result of settings or user action. Normal.
Disk array has been
deleted
Result of settings or user action. Normal.
Disk array has been
added
Result of settings or user action. Normal.
Disk array has been
removed
The physical drives of the disk array were removed
from the enclosure.
Disk array settings have
been changed
The user successfully logical drive settings. See
page 135.
Drive Interface Controller
Drive-interface controller
found
Normal.
Event Action