VTRAK M-CLASS Product Manual

VTrak M-Class Product Manual
276
Host-interface controller
settings have changed
Result of user action. Normal.
Fibre Channel
Fibre Channel controller
has detected bus reset
The initiator sent a reset command. If this message
appears repeatedly, contact Technical Support. See
page 299.
Fibre Channel controller
has received a LUN reset
command.
Result of user action. Normal.
Fibre Channel controller
has encountered a fatal
error
Restart the VTrak. See page 218. If this message
appears repeatedly, contact Technical Support. See
page 299.
Fibre Channel link is up FC link connected and ready. Normal.
Fibre Channel link is
down
FC link disconnected or otherwise not working.
Fibre Channel controller
settings have changed
Result of user action. Normal.
iSCSI
iSCSI link is up iSCSI link connected and ready. Normal.
iSCSI link is down iSCSI link disconnected or otherwise not working.
Logical Drive
Logical drive initialization
has started
Result of user action. Normal.
Logical drive initialization
has completed
Logical drive is ready to use. Normal.
Logical drive initialization
has paused
Initialization paused because of user intervention,
schedule or a higher priority background activity.
Logical drive initialization
has resumed
Initialization has resumed again after a pause.
Logical drive initialization
has stopped
Initialization stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Logical drive initialization
marks the logical drive
offline
Initialization failure due to a failed disk drive. Replace
the disk drive, delete and recreate the logical drive.
See page 16 and page 135.
Event Action