VTRAK M-CLASS Product Manual

Chapter 8: Troubleshooting
277
Logical drive initialization
is aborted due to an
internal error.
System resources are low. Reduce system load or
restart the VTrak. See page 218.
Logical drive initialization
is queued
Initialization has been set manually or by schedule.
A new logical drive has
been created
Result of user action. Normal.
Logical drive has been
deleted
Result of user action. Normal.
Logical drive has been
placed online
The physical drives of the array are restored to online
status.
Logical drive has been
placed online. Possible
data loss
One or more physical drives in the array went offline.
See page 286.
Logical drive has been set
to critical.
One or more physical drives in the array went offline.
See page 286.
Logical drive axle has
been placed online
RAID 50. One of the axles (RAID 5 arrays) returned
on online status.
Media Patrol
Media patrol is started Result of settings or user action. Normal.
Media patrol is completed Normal.
Media patrol is paused Media patrol paused because of user intervention,
schedule or a higher priority background activity.
Media patrol is resumed Media patrol has resumed again after a pause.
Media patrol is stopped Media patrol stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Media patrol is aborted
due to an internal error.
System resources are low. Reduce system load or
restart the VTrak. See page 218.
Media patrol is queued Media patrol has been set manually or by schedule.
Media patrol is stopped
internally
Media patrol stopped because the disk array was
deleted or removed.
Online Capacity Expansion
Online capacity
expansion has started
Result of settings or user action. Normal.
Event Action