Product manual

VTrak E-Class Product Manual
216
The condition is cleared. See “Physical Drive Problems” on page 399 for more
information.
Making Controller Settings
If your subsystem has two controllers, any settings you make to one controller
automatically apply to the other controller.
To make Controller settings:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Controller Management and press Enter.
3. Highlight the controller you want and press Enter.
4. Highlight Controller Settings and press Enter.
5. Make the following settings as required:
Type an alias into the Alias field.
Maximum of 48 characters. Use letters, numbers, space between words
and underscore. An alias is optional.
Highlight LUN Affinity and press the spacebar to toggle between
Enabled and Disabled.
RAID controllers must be set to Active-Active. See“Making Subsystem
Settings” on page 211 and “LUN Affinity” on page 361.
Highlight Coercion and press the spacebar to toggle between Enabled
and Disabled.
For more information, see “Capacity Coercion” on page 364.
Highlight Coercion Method and press the spacebar to toggle through:
GB Truncate – Reduces the capacity to the nearest 1 GB boundary.
10 GB Truncate – Reduces the capacity to the nearest 10 GB
boundary.
Grp (group) Rounding – Uses an algorithm to determine truncation.
Results in the maximum amount of usable drive capacity.
Table Rounding – Applies a predefined table to determine truncation.
Highlight Host Cache Flushing and press the spacebar to toggle
between Enable and Disable.
For more information, see “Host Cache Flushing” on page 363.
Highlight Cache Flush Interval and press the backspace key to erase
the current value. Type a new interval value.
The range is 1 to 12 seconds. For more information, see “Cache Policy”
on page 362.
Highlight SMART and press the spacebar to toggle between Enable
and Disable.