Chapter 5: Management with the CLU
261
Optional. Highlight TargetAlias and type an alias into the field provided.
Highlight each item and press the Spacebar to toggle between Enable
and Disable.
HeaderDigest – Adds a header digest (CRC).
DataDigest – Adds a data digest (CRC).
UniCHAPAuthen – Enables uni-directional CHAP authentication.
BiCHAPAuthen – Enables bi-directional CHAP authentication.
Authentication requires a pre-existing CHAP.
6. Highlight Save Settings and press Enter.
The Add Portals screen appears.
7. Highlight each portal that you want to assign to the new target and press the
Spacebar to mark it.
If a portal is marked, highlight and press the Spacebar to un-mark it.
8. When you have maked the portals you want, highlight Save Settings and
press Enter.
9. Press Y to confirm.
The revised target appears.
10. Press Return to Previous Menu to return to the iSCSI targets list.
Deleting iSCSI Targets
You cannot delete the default target. Using the CLU, to unassign a portal from a
target, you must delete the target.
To delete an iSCSI target:
1. From the Main Menu, highlight iSCSI Management and press Enter.
2. Highlight iSCSI Targets and press Enter.
The list of iSCSI Targets displays.
3. Highlight the target you want to delete and press the Spacebar to mark it.
4. Highlight Delete Marked Targets and press Enter.
5. Press Y to confirm deletion.
6. Press Y again to acknowledge possible interruption of iSCSI services.
The target is removed from the list.
Viewing a List of iSCSI Ports
An iSCSI port is the physical iSCSI connection on the VTrak. There are four
iSCSI ports on each RAID controller for a total of eight per subsystem.
To view a list of iSCSI ports: