Product manual

Chapter 2: Installation
31
Fibre Channel SAN – No Single Point of Failure
An FC SAN with no single point of failure (NSPF) requires:
An FC HBA card in each host PC or server
An SFP transceiver for each connected FC port on the subsystem
Two SFF-8088 4X to SFF-8088 4X SAS external cables for each JBOD unit
Two FC switches
A network switch
Data Path
To establish the data path:
1. Connect an FC cable between an FC data port on the left RAID controller
and one of the FC switches.
See page 32, Figure 15.
2. Connect an FC cable between an FC data port on the left RAID controller
and the other FC switch.
3. Connect an FC cable between an FC data port on the right RAID controller
and one of the FC switches.
4. Connect an FC cable between an FC data port on the right RAID controller
and the other FC switch.
5. Connect FC cables between one of the FC switches and the FC HBA cards
in both of the host PCs or servers.
6. Connect FC cables between the other FC switch and the FC HBA cards in
both of the host PCs or servers.
If you have multiple VTrak subsystems, repeat steps 1 through 6 as required.
Important
For a list of supported HBAs, switches, and SFP transceivers,
download the latest compatibility list from PROMISE support:
http://www.promise.com/support/.
Note
For multipathing (MPIO) applications, see:
“Appendix B: Multipathing on Windows” on page 363.