ELECTRO-GEN OPERATOR’S MANUAL Thermal Fogger - Electric Sprayer For safe operating and maintenance instructions read carefully.
PRORESTORE PRODUCTS ELECTRO-GEN™ OPERATOR'S MANUAL Copyright © 2010 ProRestore Products Coraopolis, PA 15108 Reproduction in any manner, in whole or in part, in English or in other languages is prohibited. All Rights Reserved.
Table of Contents Operating Principle of the Electro-Gen™ Fogger...................................... 1 Cold Spraying Mode.................................................. 1 Thermal Fogging Mode............................................. 1 Specifications............................................................. 2 Warnings.................................................................... 2 Cautions..................................................................... 3 Equipment Preparation..........
OPERATING PRINCIPLE OF THE ELECTRO-GEN™ FOGGER The ELECTRO-GEN UNIT is a dual purpose chemical application device: A THERMAL FOGGER which produces a very small size droplet particle and an optional electric sprayer which produces a cold mist spray similar to that produced by an aerosol can. COLD SPRAYING MODE At the touch of the trigger, an electric pump draws solution from the solution reservoir.
SPECIFICATIONS: MOTOR: Electro-Mechanical (vibrator) 7,200 strokes per minute Rating - refer to rating on plate PUMP: Displacement Type - Output-Spraying: 1 ounce (30ml) per minute - Fogging: 1,000 cubic feet (28 cubic meters) per minute Particle Size - Cold Spraying: 115 microns in diameter - Fogging: 13.
• Fog produced is flammable. Do not fog near open flames such as gas burners, or pilot lights. • Insecticidal fogs may be toxic. Do not inhale fog. • Do not fog around food, eating utensils, humans, pets, or animals. • The odor of this product like many common household products with an odor may irritate those who have allergic sensitivity. • Cautions for the potentially sensitive: evacuate area prior to treatment.
1. Fill container with appropriate solution to be sprayed. The sprayer works effectively with most deodorants, disinfectants, garden sprays, mothproofers, and insecticides. Wettable powders and resinous materials such as DUCT SEALANTS are not recommended as they will clog pumping mechanism. 2. Attach chemical reservoir and pull trigger to prime unit and spray. B.
ADVANTAGES OF THERMAL FOGGING 1. Smaller particles penetrate cracks and dense areas more thoroughly than mist sprays. 2. Thermal fogging is recommended for treatment of large areas. 3. Thermal fogging is less likely to build-up an oily residue on plants, furniture, etc. unless over applied. Most insecticides are applied at a suggested rate of 1 ounce (30ml) per thousand cubic feet of space. A 15-20 second application generally covers a 1,000 cubic foot (28 cubic meters) area.
flushing agent. Thus you've doubled your chances of exposing the insects to a lethal dose of insecticide. Remember: Only the proper product, utilized in the proper concentration, applied over the recommended area will give satisfactory results. DEODORIZATION TIPS ® Thermal fogging is the third step in the Unsmoke Structural Smoke Odor Removal Procedure. Prior to thermal fogging: Step 1 Suppress odor sources such as charred wood, or horizontal structural surfaces, etc.
Proper Product Selection For The ODORx Thermo 55 Odor Counteractant Series The ODORx Thermo 55 series is the restoration industry's most effective thermally activated fogging odor counteractant. The ODORx Thermo 55 Series is compounded from the purest base materials and finest aroma ingredients available. The Thermo 55 Odor Counteractants have been used internationally on over 2,000,000 successful smoke odor removal applications. Thermo 55 Neutral Excellent general purpose smoke odor counteractant.
Maintenance Cleaning Your Electro-Gen Unit After Use As A Sprayer Clean and purge system by spraying water with a small amount of suitable detergent through unit. Rinse system by spraying clear water through unit. Wash solution reservoir with detergent and water solution, rinse with clear water and wipe dry after each use. Remove the filter, thoroughly wash, rinse, and replace filter.
Winterizing Protect unit utilizing water based formulations from freezing if unit is to be transported, or stored in an area where freezing is likely. Drain solution reservoir, and spray some winterized windshield cleaning solution through unit. Solvent based formulations such as ODORx® THERMO 55™ do not freeze, so when utilizing solvent based formulations no special winterizing procedure is necessary. Clogging Foreign matter in the liquid can result in clogging the pump or nozzle.
CAUSE Normal motor noise Insufficient solution level Nozzle cap plugged Check to see if the valve is stuck Nozzle orifice broken Nozzle loose Low input voltage Over-adjusted Pump bound Improper adjustment Worn/damaged nozzle Dirty/contaminated formulation. Nozzle leakage. Internal leakage. Worn piston & o-ring seal. PROBLEM Buzzing sound Motor runs but no spray is emitted Flame from heating element Motor hums - no spray (bound) Poor Spray Leakage Tighten nozzle. Replace piston and o-ring seal.
PARTS LIST KEY PART NO. QTY. DESCRIPTION 1 102259001 1 3 qt. (2.
4660 Elizabeth Street Coraopolis, PA 15108 Copyright 2010 ProRestore Products