User manual
1560-PDP 
PROFIBUS – SCANport Adapter 
  17   
Vendor_Name  = "ProSoft Technology Inc" 
Model_Name  = "1560-PDP SCANport Adapter" 
Revision   = "Rev 1.0 - 1"; 
Ident_Number = 0x087C  ; Need official ID from PTO 
Protocol_Ident = 0  ; 0 = Profibus DP 
Station_Type = 0  ; 0 = DP Slave 
FMS_supp   = 0  ; No FMS support 
Hardware_Release = "01"  ; Not a function of Hardware Release 
Software_Release = "1"  ; Batch Number 
; 
; Supported Baud Rates 
9.6_supp   = 1 
19.2_supp  = 1 
93.75_supp  = 1 
187.5_supp  = 1 
500_supp   = 1 
1.5M_supp  = 1 
3M_supp  = 1 
6M_supp  = 1 
12M_supp  = 1 
; 
; Maximum Responder time for supported baud rates 
MaxTsdr_9.6   = 60 
MaxTsdr_19.2   = 60 
MaxTsdr_93.75   = 60 
MaxTsdr_187.5   = 60 
MaxTsdr_500   = 100 
MaxTsdr_1.5M   = 150 
MaxTsdr_3M   = 250 
MaxTsdr_6M   = 450 
MaxTsdr_12M   = 800 
; 
; Supported hardware features 
Redundancy = 0        ; Not supported 
Repeater_Ctrl_Sig = 2      ; TTL 
24V_Pins = 0        ; Not Connected 
Implementation_Type= "SPC3" 
; 
; 
; 
; Supported DP Features 
Freeze_Mode_supp  = 1      ; supported 
Sync_Mode_supp   = 1      ; supported 
Auto_Baud_supp   = 1      ; supported 
Set_Slave_Add_supp= 0      ; DIP Switch config address 
; 
; 
; 
; Maximum Polling Frequency 
Min_Slave_Intervall = 1    ; 100 us 
; 
; Device Type 
Slave_Family   = 1      ; 1 = Drives 
; 
; Maximum supported sizes 
Modular_Station  = 1      ; Compact station - Predefined I/O 
Max_Module = 5 