User manual
1560-PDP 
PROFIBUS – SCANport Adapter 
  21   
E.2 : Adapter Status Image (Read from 1560-PDP) 
Word Name Values Description
0 SCANport Status 0 = Offline 
1 = Online
Indicates if 1560-PDP is logged 
into the drive. If drive is 
powered down or if SCANport 
cable becomes disconnected, 
the value will go to offline
1 Control/Reference 
Command Counter
0 to 
0xFFFF
This is a rollover counter which 
increments each time the 1560-
PDP received a Status word 
update from the SCANport 
device
2 Datalink A update 
counter
0 to 
0xFFFF
This is a rollover counter which 
increments each time the 
Datalink A update is received 
from the SCANport device
3 Datalink B update 
counter
0 to 
0xFFFF
This is a rollover counter which 
increments each time the 
Datalink B update is received 
from the SCANport device
4 Datalink C update 
counter
0 to 
0xFFFF
This is a rollover counter which 
increments each time the 
Datalink C update is received 
from the SCANport device
5 Datalink D update 
counter
0 to 
0xFFFF
This is a rollover counter which 
increments each time the 
Datalink D update is received 
from the SCANport device
6 Parameter Read 
Update Counter
0 to 
0xFFFF
This is a rollover counter which 
increments each time a Rad 
Parameter command is 
received from the SCANport 
device
7 Parameter Write 
Update Counter
0 to 
0xFFFF
This is a rollover counter which 
increments each time a Write 
Parameter command is 
executed
8
Profibus Status
(Future)
9 Product Revision Provides the firmware revision 
level. The data should be 