Problem Description 
Steps to take 
The green LED blinks 
slowly but the module 
does not send or 
respond to text 
messages 
This indicates a problem with backplane communication to the controller. 
Verify that 
  The controller is in RUN or REM RUN mode 
  The module is plugged into the slot that has been configured for it in 
the controller program 
  The module is connected to the cellular carrier when the module 
boots up. If there is no connection to the carrier when the module 
boots up, the configuration message retries from the controller to the 
module will time out. Without a configuration, the module will not 
function properly. If you suspect that this has occurred, troubleshoot 
wireless network connectivity, then reboot the module by cycling 
power to the controller. 
  The controller program handles all read and write situations, and all 
four function blocks for the ILX800-SMSG are present in the Project 
Organizer pane 
The module's status 
variables in CCW never 
change from '0' after the 
module boots up 
Verify that 
  CCW is online with the controller and in debug mode 
  There is backplane communication between the controller and the 
module (see above) 
5.3  Status Data 
Useful status data for the ILX800-SMSG plug-in module can be found in the Local Variables 
for the PSFT_ILX800_SMSG program. 
The status data is contained in variables with the STATUS_ prefix. 
Hint: Click the header of the NAME column to sort the variable list alphabetically. This will group all the STATUS 
variables together. 
For these status values to be visible, CCW must be online with the processor, and the 
Debug function in CCW must be running. (See Going Online with the Controller.) 