User manual
Table Of Contents
- Start Here
- Configuring the Processor with Concept
- Configuring the Processor with ProWORX
- Configuring the Processor with UnityPro XL
- To build (compile) the project:
- To verify address and driver settings in UnityPro XL:
- Setting Up the ProTalk Module
- Configuring the Module
- Diagnostics and Troubleshooting
- Reading Status Data From the Module
- The Configuration/Debug Menu
- Required Hardware
- Required Software
- Using the Configuration/Debug Port
- Main Menu
- Opening the Data Analyzer Menu
- Viewing Block Transfer Statistics
- Viewing Module Configuration
- Opening the Database Menu
- Opening the Backplane Menu
- Transferring the Configuration File from PC to PTQ module
- Transferring the Configuration File from PTQ module to PC
- Viewing Version Information
- Warm Booting the Module
- Viewing Port Communication Status
- Viewing Port Configuration
- Exiting the Program
- Database View Menu
- Viewing Register Pages
- Displaying the Current Page of Registers Again
- Moving Back Through 5 Pages of Registers
- Viewing the Previous 100 Registers of Data
- Skipping 500 Registers of Data
- Viewing the Next 100 Registers of Data
- Viewing Data in Decimal Format
- Viewing Data in Hexadecimal Format
- Viewing Data in Floating Point Format
- Viewing Data in ASCII (Text) Format
- Returning to the Main Menu
- Backplane Menu
- Data Analyzer
- Data Analyzer Tips
- LED Status Indicators
- Reading Status Data From the Module
- Reference
- Index
Reference PTQ-LNG ♦ Quantum / Unity Platform
Landis & Gyr Telegyr Interface Module
ProSoft Technology, Inc. Page 83 of 103
May 29, 2007
o Accumulators: 50 points
o Indication Points: 800 points
Supported Function Codes
Code Description
0 Analog Change Report
1 Analog Force Report
2 Analog Group Change Report
3 Analog Group Force Report
5 ADC Reference Force Report
6 Indication Change Report
7 Indication Force Report
11 Digital Input Force Report
12 Accumulator Change Report
13 Accumulator Force Report
20 Analog Report
21 SBO Select
22 SBO Operate
23 Digital Output
24 Accumulator Freeze
25 Pulse Output
26 Pulse Train Output
30 Restart RTU
31 RTU Configuration
32 Time Synchronization
34 Analog Deadbands
35 Analog Group Define
36 Accumulator Preset
37 Continuation Request
38 Repeat Last Message
39 Firmware Configuration
8.2 PTQ-LNG Functionality Overview
This section gives the reader a functional overview of the PTQ-LNG module.
A thorough understanding of the information contained in this document is
required for successful implementation of the module in a user application. If you
already understand the content of this section, refer to the Module
Configuration section to install and configure the module. If you are not familiar
with the data transfer method used by the module, read this section before
installing and configuring the module.