TheRLX2radiosacceptpowerfrom802.3afModeBorpassivePoweroverEthernet
sourcessupplying48VDC,withanaveragepowerdrawoflessthan8watts.ProSoft
offersthefollowingpassivePoEinjectorsforusewiththeRLX2radios:
POE48IAC PoweroverEthernetInjector,ACinput
POE48IDCDC PoweroverEthernetInjector,9to36VDCinputvoltage
Theradioshallbeinstalledbytrainedpersonnelonly,asoutlinedintheinstallation
instructionsprovidedwitheachradio.
Theequipmentshallbeinstalledbyaqualifiedinstaller/electri cian.The
installer/electricianisresponsibleforobtainingasecuredgroundconnectionbetween
thelugterminalonthesurgeprotectortoaverifiedcommongroundpointusi
nga
minimum6AWGgaugewire.Thismustbedonewhenattachingpowerlinestothe
radioduringinstallation.
Asolidgroundconnectionshouldbeverifiedusingameterpriortoapplyingpowerto
theradio.Failingtosecureapropergroundcouldresultinseriousinjuryordea
thasa
resultofalightningstrike.
UsingPoweroverEthernet(PoE)topowerremotedeviceshasseveraladvantages
including:
"CarrierClass"PowerOverEthernetSystem.
Powercanbesuppliedoverlongdistances,upto300feet.