SDS

Safety Data Sheet
ProSpec
®
Stone Veneer Sealant
© TCC Materials
Version 1.0
Page 8 of 15
Stoddard solvent
OSHA PEL PEL 500 ppm 2,900 mg/m3 ;
ACGIH TLV TWA value 100 ppm ;
Advice on system design:
Provide adequate exhaust ventilation to control work place concentrations.
Personal protective equipment
Respiratory protection:
When workers are facing concentrations above the occupational exposure limits they
must use appropriate certified respirators. When atmospheric levels may exceed the
occupational exposure limit (PEL or TLV) NIOSH-certified air-purifying respirators
equipped with an organic vapor sorbent and particulate filter can be used as long as
appropriate precautions and change out schedules are in place. For emergency or non-
routine, high exposure situations, including confined space entry, use a NIOSH-certified
full facepiece pressure demand self-contained breathing apparatus (SCBA) or a full
facepiece pressure demand supplied-air respirator (SAR) with escape provisions.
Hand protection:
Chemical resistant protective gloves should be worn to prevent all skin contact. Suitable
materials may include, chloroprene rubber (Neoprene), nitrile rubber (Buna N),
chlorinated polyethylene, polyvinylchloride (Pylox), butyl rubber, depending upon
conditions of use.
Eye protection:
Tightly fitting safety goggles (chemical goggles). Wear face shield if splashing hazard
exists.
Body protection:
Cover as much of the exposed skin as possible to prevent all skin contact. Suitable
materials may include, saran-coated material, depending upon conditions of use.
General safety and hygiene measures:
Avoid contact with the skin, eyes and clothing. No special measures necessary if stored
and handled correctly. Handle in accordance with good building materials hygiene and
safety practice. Wearing of closed work clothing is recommended. Wear protective
clothing as necessary to prevent contact. Eye wash fountains and safety showers must
be easily accessible. Observe the appropriate PEL or TLV value. Wash soiled clothing
immediately. Contaminated equipment or clothing should be cleaned after each use or
disposed of.
Section 9: Physical and Chemical Properties
Form: paste
Odour: mild