Photo Printer User Manual

COMPACT 2
TM
13
Operation
English
®
Time Replenishment (Antioxidation function, Flood replishment)
Also during the stand-by, the developer chemicals are subject to change which
causes their deterioration. By means of the time replenishment, a replenishment cy-
cle is activated after a set time. With this function, the quality of the developer chem-
icals are maintained even when standing idle for long periods. The setting-range for
the time-replenishment is from 5 up to 99 minutes. When “0” is set, the time-replen-
ishment is de-activated.
Setting of time-replenishment:
1. Switch processor off.
2. Press the buttons processing speed (4) and replenishment time developer (7)
simultaniously and keep pressed.
3. Switch the machine on again and release the pressed buttons.
4. Select the replenishment interval time (min.) by pressing the arrow buttons (2
and 3). The arrow up button (2) increases and the arrow down button (3)
decreases the value.
5. Switch machine off again.
Example: At the setting “45” a replenishment cycle is activated every 45 minutes.
Working Parameters
The processing machine develops, fixes, rinses and dries the film materials auto-
matically. The film and chemical requirements can be adjusted accordingly and
stored in the control unit.
Display of working parameters:
1. Switch processor on.
2. Press the respective mode button (4-8) and keep pressed to display the
required working parameter or Press the respective mode button (4-8) and
release to display the momentary value.
Setting the working parameters:
1. Switch processor on.
2. Machine must be in the stand-by mode and no film must be in the processor.
3. Press the respective mode button (4-8) and keep pressed: The display shows
the set working parameter.
4. Change value by means of the arrow buttons (2 and 3) until required value
appears on the display. The upward arrow button (2) increases and the down-
ward arrow button (3) decreases the value.
5. Release the mode button.