Problems and Solutions
®
Advice on Machine Errors
Replenishment rate too high
Check the programmed times of replenishment cycle and replenishment time.
Replenishment rate too low
Check the programmed times of replenishment cycle and replenishment time.
Check whether the machine can be started by each of the light barriers (4
pieces). In the case of a light sensor being faulty, call your service technician.
In the meantime, double the programmed replenishment time.
Replenishment pump does not pump
Check whether the replenishment containers are full and that the end of the
suction pipe is positioned under the liquid level.
Check whether there is air in the replenishment pipes. If this is the case, then
check the pipe connections.
Water tank overflows
Water drainage hose (overflow) is bent. The hose end should be positioned
above the drainage level in the syphon.›‹›‹
Check water drainage in the tank and hose for blockage and pollution. The
drainage hoses should have a constant fall.
The film does not transport correctly
Film is fed in and gets caught in the machine: Check the positioning of the
racks in the machine and make sure that the latches are closed.
Film cannot be fed, the display shows “E1”
Close machine cover securely, paying special attention that the switch on the
rear of the control panel is actuated.
Film is in the infeed and nothing happens
Display is flashing: Control is in the manual mode. Switch back to Automatic
Mode (see page 16).
Developer-temperature button is flashing: The temperature of the developer
has not yet been reached. Wait until temperature has been reached and the
button stops flashing.
Push the film deep into the infeed and move this from side to side. If the proc-
essor still does not start then call your service technician. In the meantime,
with limitations the processor can be worked with in the Manual Mode (see
page 16).
Machine does not switch on
Ensure that electrical plug is firmly inserted into socket. Ensure that electrical
socket has power supply by testing with an appliance e.g. tablelight.
Rinsing water does not flow
Open water inflow tap.
Water pressure in the water system is too low: Pressure in the plumping sys-
tem too low: Minimum pressure has to be 2 bar (29 psi).