Indoor Furnishings User Manual

Page 6
REMOTE SWITCH OPERATION
Turning the Lighting Circuit On Tap the Rocker Top once.
Turn On to Full Bright Tap the Rocker Top twice.
Brightening the Lighting Circuit Hold Top down until lighting level is achieved.
Turning the Lighting Circuit Off Tap the Rocker Bottom once.
Dimming the Lighting Circuit Hold Bottom down until lighting level is achieved
LIGHTING MODULE PROGRAMMING
X-10 Addressing and Programming Interface
The X-10 protocol allows units to have a unique address made up of any combination
of a House Code (a letter from A to P) and a Device Code (a number from 1 to 16).
The most cost-effective product to program the Lighting Modules is the X-10
Maxicontroller. This unit is inexpensive and can send the full set of standard X-10
signals.
Modes of Programming
In addition to
Normal Operation
, there are five programming modes used to set the
Primary Address
, the
Scene Addresses
, the
Scene Enables, Scene Ramp Rates
and the
Advanced Programming Options.
Normal Operation
- this is the normal operating state of the Lighting Module.
Mode 1
- mode used to set primary address of the channel(s).
Mode 2
- mode used to set scene addresses to the scene numbers.
Mode 3
- mode used enable or disable individual channels to scenes.
Mode 4
- mode used to set ramp rates to the scene numbers.
Mode 5
- modes used to set the Advanced Programming Options.
Scene Number
- A number from 1 to 16 representing each scene and holds settings
for scene address, channel enable, ramp rate and lighting level.
Channel Number
- A number representing the lighting channel of product. The XP4LS
has 4 channels (Channel Numbers 1 to 4) and XP1LS has only 1 channel (Channel
Number 1).
NOTE:
Elementary programming can be performed using this instruction manual. To
fully understand the scene features of the system, please read the
X-10 PRO's
Programming Manual
which covers the complete programming of this device.
This is available free from the X-10 PRO web site (www.X10PRO.com).
The X-10 PRO lighting system will provide visual feedback while in programming mode.
Lights will flash and the LED pattern will change
during the course of programming
to give the installer feedback that his actions are being entered.