2-5. RS232/422/485 (COM2) SELECTION 
JP3 : RS-232/422/485 Selection 
COM1, COM3, & COM4 is fixed for RS-232 function only. 
COM2 is selectable for RS-232, 422, 485 function. 
The jumper settings are as follows : 
COM 2 
Function 
Jumper Setting 
(pin closed) 
Jumper 
Illustration 
RS-232 
Open 
RS-422 
1-2, 5-6, 7-8, 9-10 
11-12,13-14,15-16 
17-18, 19-20 
RS-485 
1-3, 4-6, 7-8, 9-10 
11-12,13-14,15-16 
17-18, 19-20 