Instructions

Testing the function of the roller
shutter sensor
Slowly move the roller shutter to the open position,
then the green LED on the roller shutter sensor (OPEN)
will flash briefly before the open position.
Close the roller shutter, then the red LED (CLOSED)
will flash briefly.
Instructions for attaching the
stove transmitter
AS-T30 (figures 15 and T)
NOTE
The stove should be switched off and cool in order to
avoid burns to your skin.
The distance between the installation point of the
temperature measuring device and the exhaust stack of
the room air-dependent fireplace in the connecting piece
must not exceed a maximum of 1.5 m. The temperature
sensor must extend into the exhaust gas stream by at
least 30 mm and a maximum of 100 mm, whereby
a homogeneous flow around the temperature sensor
by the core flow of the exhaust gas must be ensured.
Regular inspection and, if necessary, cleaning must be
carried out.
The thermal sensor (figure 3) is fed into the exhaust
pipe through a hole and screwed to the stove pipe using
the included mounting bracket. The stove transmitter
should not be covered by cladding as this impedes the
radio signal and reduces the range.
1. Drill a 4 mm hole in a suitable position in the exhaust
pipe for the thermal sensor. If possible ensure that the
hole is positioned in such a way that the thermal sensor
cannot be seen after attachment.
2. Slide the mounting bracket over the thermal sensor
but do not tighten the screw to attach the thermal
sensor yet.
3. Insert the thermal sensor as far as possible into the hole
that you have drilled for it.
4. Move the mounting bracket on the thermal sensor
until it is lying on the exhaust pipe and then mark the
two attachment holes on the mounting bracket with a
suitable pen. Then remove the thermal sensor and the
mounting bracket from the exhaust pipe again.
5. Drill 2 mm holes at the two positions you have marked
for mounting on the exhaust pipe.
NOTE
If you have a double-walled exhaust pipe then take
care to drill the mounting holes only through the
outer pipe.
6. Fix the mounting bracket to the exhaust pipe by
screwing it with the two included tapping screws and
the two drilled holes as described above.
EN