Instructions

Caution: A logical AND association of the sensors is
created if one sensor is fitted with the AND jumper
and the following must be an OR Sensor. Completing
the pairing process with an AND or a subsequent stove
sensor will produce an ERROR (three short, three long,
three short) and returns the central unit to the
factory reset.
If this has happened a further sensor can be taught or
maintained until the set routine is over after approx.
50 seconds. This is shown by 2 consecutive acoustic
triple signals and a change of the power LED to
constant green and the corresponding sensor LED to
the relevant status.
The exhaust system should now be functional.
When operating the system please note that the
window and roller shutter sensors have transferred the
status if they flash green twice after approx. 5 seconds.
If the relevant sensor flashes red twice then the status
was not transferred sufficiently and is sent in cycles
again every 50 seconds until the status is accepted and
confirmed as described above.
For the stove sensor the status is requested every
180 seconds. If the status of the stove sensor changes
then it is updated to the central unit in accordance with
the routine described above.
The central unit decides on the release of the relay,
which sensors were taught and what condition
they are in.
System function test
(Example AS-7020/30/40 and AS-F20
window transmitter)
Switch the exhaust device on and open the window.
The green LED flashes briefly and the green LED on the
receiver is now on constantly. The exhaust device is
switched on.
Close the window and the exhaust device will switch
off. The red LED on the transmitter flashes and the red
LED on the receiver is now on constantly. The exhaust
device is switched off.
Your system is ready for operation once this function
test has been completed. Repeat this function test at
regular intervals for your own safety.
EN
36