User's Manual

SLG BOARD
SETTINGS AND FUNCTIONS
SLG BOARD
SETTINGS AND FUNCTIONS
RED RATE OF FIRE (VALUES 1-20)
The ROF setting is used to set the
maximum rate of fire of the SLG™.
The values do not correspond directly
to a certain Balls Per Second (BPS)
value. You will need to use the table
below to locate your desired maximum
ROF setting. The factory default is 8
(14.9 BPS). This setting is used both
when the Eye function is turned
on and off.
Increasing ROF too high will increase probability of ball breakage. If this occurs decrease ROF setting.
YELLOW FIRE MODE (VALUES 1-4)
The fire mode setting is used to select the fire mode of the SLG™. Factory default is semi
automatic mode; one trigger pull shoots out one paintball. The Millennium mode and the PSP
mode follow the rules of the paintball tournament series.
Value 1 Semi automatic mode
Value 2 Millennium™ Mode
Value 3 PSP™ mode
Value 4 NXL
TO CHANGE A VALUE OF A SETTING
1. While in the configuration mode choose the color you wish to change by pulling the trigger.
2. When the LED indicates the color you wish to change, pull and hold the trigger until the LED
starts to flash.
3. The LED will flash as many times as the previous setting was and it will then turn off. Now pull
the trigger as many times as you wish the new setting to be.
4. When done the LED will cycle through all the colors again to indicate setting was saved and
turn back to green. You can now change another setting or quit the configuration mode.
1 10 BPS
2 11 BPS
3 12 BPS
4 13 BPS
5 14 BPS
6 14.5 BPS
7 14.7 BPS
8 14.9 BPS
9 15.2 BPS
10 15.4 BPS
11 15.6 BPS
12 15.9 BPS
13 16 BPS
14 18 BPS
15 20 BPS
16 22 BPS
17 24 BPS
18 26 BPS
19 28 BPS
20 30 BPS
Normal Mode Configuration Mode
W W W . P R O T O P A I N T B A L L . C O MW W W . P R O T O P A I N T B A L L . C O M
8
9