42580 SAWPK46 2 PACK 46" / 500 LB INDIVIDUAL CAPACITY LIGHTWEIGHT ALUMINUM SAWHORSE KIT WITH MULTI-POSITION MOUNTING BRACKETS PRODUCT MANUAL SCAN TO WATCH PRODUCT ASSEMBLY VIDEO CAUTION: To reduce the risk of injury, user must read and understand this product manual. Save these instructions for future reference. PROT OC OL E QU I P M E N T.
TABLE OF CONTENTS Features and Specifcations ...................................................................................................................... 4 Preparing the Workstation..................................................................................................................... 5-6 Installing the Tool Holders / Handles .................................................................................................. 7-8 Attaching Slim Profle Tool Mounts to Your Miter Saw ......
FEATURES AND SPECIFICATIONS 46" 5 1 2 46" 3 6 7 11 4 8 9 29" 10 j T 24" l SPECIFICATIONS INCLUDED FEATURES 46" SAWHORSE HEIGHT 29" WIDTH 46" 1 Aluminum chassis DEPTH MAX WEIGHT CAPACITY EACH UNIT MATERIAL 24" 2 High impact plastic top 500 lb. 3 Tool holder / handle Aluminum, Steel, Nylon 4 Folding legs with non-marring feet 46" SAWHORSE WEIGHT 17.6 lb. 5 Double-ended handles with built-in wheels 46" MITER SAW STAND WEIGHT 19.8 lb.
PREPARING THE WORKSTATION 1. Place workstation on a flat and level surface with folded legs facing up. 2. Turn leg lock handle counterclockwise and unfold first set of legs from chassis. CROSS BRACE 3. Deploy first set of legs. Make sure cross brace is secured in place to ensure legs are fully opened. 4. Unfold second set of legs and follow step #3. FIND OUT MORE AT PROTOCOLEQUIPMENT.
PREPARING THE WORKSTATION 5. After both sets of legs are deployed, lift workstation in an upright position. - '- ~ I- 0. 6. ~ ~' Ensure workstation is stable and both sets of legs are fully opened. 6 FIND OUT MORE AT PROTOCOLEQUIPMENT.
INSTALLING THE TOOL HOLDERS / HANDLES Tools Required: 4 mm hex key (not included) Counter Sunk Screw x 6 1. Locate holes at the bottom of the tool holder. 2. Place one nylon nut underneath holder and align nut to hole. FIND OUT MORE AT PROTOCOLEQUIPMENT.
INSTALLING THE TOOL HOLDERS / HANDLES 3. Find corresponding hole on chassis. 4. Insert screw from interior side of chassis. 5. Use a 4 mm hex key to attach tool holder to chassis. 6. Repeat steps #2 through #5 to secure other end of tool holder. 7. Repeat steps #1 through #6 to attach the remaining tool holders. 8 FIND OUT MORE AT PROTOCOLEQUIPMENT.
ATTACHING SLIM PROFILE TOOL MOUNTS TO YOUR MITER SAW Tools Required: 4 mm hex key (not included) Slim Profle Tool Mount x 2 Carriage Bolt x 4 O-ring x 4 Flat Washer x 4 Spring Washer x 4 M8 Nut x 4 1. Make sure your miter saw is unplugged and saw arm is locked in the down position. 2. Place miter saw on a flat, stable surface. FIND OUT MORE AT PROTOCOLEQUIPMENT.
ATTACHING SLIM PROFILE TOOL MOUNTS TO YOUR MITER SAW 3RD HOLE 1ST HOLE 3. FOR OVERHANG MOUNTING: Tool mounts are pre-installed for overhang mounting. Stair steps should already be installed in first and third holes starting from tool mount handle side. 4TH HOLE 2ND HOLE I 4. 1 FOR CENTER MOUNTING: Use 4 mm hex key to loosen screws and remove stair steps from tool mount. Reinstall stair steps into second and fourth holes. Make sure stair steps are facing away from tool mount handle.
ATTACHING SLIM PROFILE TOOL MOUNTS TO YOUR MITER SAW 7. Place tool mount under one side of your miter saw. Maneuver miter saw over tool mount and feed pre-installed carriage bolts into mounting holes. M8 NUT SPRING WASHER FLAT WASHER CARRIAGE BOLT 8. Place a flat washer, spring washer, and M8 nut onto carriage bolts. FIND OUT MORE AT PROTOCOLEQUIPMENT.
ATTACHING SLIM PROFILE TOOL MOUNTS TO YOUR MITER SAW 9. Repeat steps #5 through #8 to attach second tool mount to your miter saw. 10. Ensure both tool mounts are parallel to one another, and finger-tighten all four M8 nuts to hold in position. 12 FIND OUT MORE AT PROTOCOLEQUIPMENT.
ATTACHING SLIM PROFILE TOOL MOUNTS TO YOUR MITER SAW NOTE: If your miter saw mounting holes DO NOT line up with tool mount slots and tool mounts are not parallel to each other when mounted: a. Make sure your miter saw is unplugged and saw arm is locked in the down position. b. Mount miter saw to a mounting surface at least 3/4” thick using required bolts, washers, and nuts for your miter saw. c. Drill holes in mounting surface to match position of tool mount slots. d. Proceed with installation.
MOUNTING MITER SAW ASSEMBLY TO THE STAND Tools Required: 13 mm socket or wrench (not included) 1. Turn tool mount handles counterclockwise until stair steps are fully retracted. LOWER THE BACK FIRST 2. Carefully lift miter saw assembly and tilt it slightly away from your body. 3. Lower the back of miter saw assembly first, placing stair steps inside back rail. 14 FIND OUT MORE AT PROTOCOLEQUIPMENT.
MOUNTING MITER SAW ASSEMBLY TO THE STAND 4. Lower front of your miter saw assembly to sit flat into chassis. 5. Slide miter saw assembly left or right to desired position. 6. Turn both tool mount handles clockwise until stair steps are engaged and miter saw assembly is secured in place. NOTE: Do not overtighten – turn one half of a rotation after resistance is felt. 7. Ensure weight of miter saw assembly is evenly balanced over chassis and adjust position if necessary. 8.
REMOVING MITER SAW ASSEMBLY FROM THE STAND 1. Turn tool mount handles counterclockwise until stair steps are fully retracted. LIFT THE FRONT FIRST 2. Lift front side of miter saw assembly until it is above the front rail. 3. Pull and lift miter saw assembly to disengage from back rail. 4. Place miter saw assembly on a flat, stable surface. 16 FIND OUT MORE AT PROTOCOLEQUIPMENT.
TRANSPORTING AND STORING THE WORKSTATION CROSS BRACE 1. Refer to instructions for REMOVING MITER SAW ASSEMBLY FROM THE STAND. 2. Carefully flip the stand over so that legs are facing up. 3. Fold first set of legs by pressing on cross brace to bring legs together. Push legs down until fully nested into chassis frame. 4. Repeat step #3 to fold second set of legs. 5. Turn leg lock to secure legs in place. FIND OUT MORE AT PROTOCOLEQUIPMENT.
TRANSPORTING AND STORING THE WORKSTATION HANDLE WHEELS 6. Use handles with built-in wheels on either side of chassis to transport workstation to desired location. SAFETY AND WARNINGS SAFETY INSTRUCTIONS FOR WORKSTATIONS 1. Use caution when folding or unfolding legs to limit any finger pinch points. 2. Place workstations on flat and level surface to keep from rocking or tipping. 3. Do not exceed the rated capacity on main frame table/chassis. 4. Ensure load is equally distributed. 5.
SAFETY AND WARNINGS GENERAL SAFETY INSTRUCTIONS FOR POWER TOOLS Using power tools of any kind can be dangerous if safe operating procedures are not followed. Recognizing the hazards of each tool and using them with respect and caution will considerably limit the possibility of personal injury. However, if safety precautions are ignored, personal injury can likely result. Always use common sense - your personal safety is your responsibility. 1. Know your power tool.
02.17.2023 JS PRODUCTS • 6445 MONTESSOURI STREET • LAS VEGAS, NV 89113 CUSTOMER SERVICE: 1-877-707-6449 • PROTOCOLEQUIPMENT.