User Manual

INSTALLATION AND MAINTENANCE MANUAL
LYNX.sc E1 FAMILY
SPREAD SPECTRUM RADIOS
OCTOBER 1998
SECTION 3: INSTALLATION & ADJUSTMENTS PAGE 3-49
3.14.3.1 Diagnostics Port using RS-232
For RS-232 diagnostics connection to the LYNX.sc radio, connect the serial device (modem,
computer, terminal) to the male 9-pin subminiature connector in accordance with Figure 3-23.
Figure 3-23: RS-232 Diagnostic Port Connections
Pins 6 through 9 must not be connected for RS-232
communications to operate properly.