Software Guide
Tsunami
®
800 & 8000 Series - Software Management Guide 311
LACP - Device Management
Tsunami Quickbridge
®
devices that are part of the LACP link cannot be managed through the switches, so it is
recommended to use the second Ethernet port for management.
:
ú
When using second Ethernet port for management, ensure to disable Auto Shutdown for Ethernet2. See
H I J K
L M
I J N K O P
).
ú
STP/LACP Frames should be set to passthru. See
Q R S J T U R P V W X U R N V T Y P S Z [
In this chapter, we have chosen the following two examples to explain the device management in the LACP link, by using the
second Ethernet port.
Example1
Figure D-1 Device Management with No VLAN
: The second Ethernet port is POE out; it should be connected via a passive POE (Without the AC power
plugged-in) or Gigabit 48 VDC Injector (GIG-POE-INJ-48VDC-T) (without 48 VDC power plugged-in).
Directly connecting the Ethernet port2 of the device to the PC Ethernet NIC may damage the PC NIC port
or Ethernet port on the switch.