Note: The following instructions assume that you will slide the SU’s mounting bracket/pole assembly onto a pole. If
this is not practical (for example, the pole is too tall or its top and bottom are permanently mounted to struc-
tures), follow the steps below, but assemble the mounting bracket/pole assembly around the pole.
1. Insert the two U-bolts into the mounting clamp housing and attach the two #5/16 nuts and 5/16 flat
washers.
2. Slide the mounting clamp housing/pole clamp assembly down the pole.
Figure 17. Mounting Clamp Housing and U-Bolts Attached
3. Squeeze the sides of the mounting clamp housing and slide it inside the flange protruding from the
back of the SU until the pins extend into the holes on the side of the flange.
Figure 18. Mounting Bracket Attached to SU
Chapter 3. Deploying the Subscriber Unit (SU) 32