Installation Instructions

Antenna Type Manufacturer Model Number Mid-band Gain (dBi)
1 Foot Flat Panel Gabriel DFPD1-52 23.5
Andrew FPA5250D12-N 23.6
2 Foot Flat Panel Gabriel DFPD2-52 28
Andrew FPA5250D24-N 28.2
2 Foot Parabolic Gabriel SSP2-52B 28.5
Gabriel SSD2-52A 28.4
Gabriel HSSP2-52 28.1
Radio Waves SP2-5.2 28.3
Radio Waves SPD2-5.2 28.1
Andrew P2F-52 29.4
Andrew PX2F-52 29.4
3 Foot Parabolic Radio Waves SP3-5.2 31.4
Radio Waves SPD3-5.2 31.1
Andrew P3F-52 33.4
Andrew PX3F-52 33.4
4 Foot Parabolic Gabriel SSP4-52A 34.2
Gabriel SSD4-52 34.1
Gabriel HSSP4-52 33.9
Radio Waves SP4-5.2 34.6
Radio Waves SPD4-5.2 34.4
6 Foot Parabolic Gabriel SSP6-52A 37.5
Gabriel SSD6-52 37.4
Gabriel HSSP6-52 37.2
Radio Waves SP6-5.2 37.7
Radio Waves SPD6-5.2 37.5
8 Foot Parabolic Gabriel SSP8-52 39.8
Gabriel SSD8-52 39.7
Gabriel HSSP8-52 39.6
Feeder Loss Type Manufacturer Model Number Loss/100' Notes
1/2" foam coax Andrew LDF 4-50 6.6 dB add ~0.25 dB per connector
5/8" foam coax Andrew LDF 4.5-50 4.7 dB add ~0.25 dB per connector
Waveguide Andrew EW-52 1.2 dB does not include transitions
Formula for determining maximum output power setting for 5.25-5.35 GHz U-NII (LE-LAN) Transmitters (@ EIRP=30dBm):
Max Tx (dBm) is the lesser of 23dBm and 30 - G + FL
where: G = Antenna Gain
FL = Feeder Loss including connectors
Note:
All Western Multiplex radios require professional installation.
Antennas with gain less than 23.5 dBi are not allowed
Antennas of other make may be used with the HZB-U53-45 device, but must be of the same type, dimensions and gain as those listed

Summary of content (1 pages)