Network Router User Manual

69
Performing Advanced Configuration
Alarms
This tab has three sub-tabs.
Groups
Alarm Host Table
Syslog
Rogue Access Point Detection (RAD)
Groups
The AP can be configured to generate and send alarms/notifications/traps as version 1 or a version 2c. Use the
drop-down menu to select SNMP alarm type.
There are seven alarm groups that can be enabled or disabled via the Web interface. Place a check mark in the box
provided to enable a specific group. Remove the check mark from the box to disable the alarms. Alarm Severity Levels
vary.
Figure 4-17 Syslog Configuration Screen
Configuration Trap Group
Trap Name Description
DNS IP Address not Configured oriTrapDNSIPNotConfigured
RADIUS Authentication not Configured oriTrapRADIUSAuthenticationNotConfigured
RADIUS Accounting not Configured oriTrapRADIUSAccountingNotConfigured
Duplicate IP Address Encountered oriTrapDuplicateIPAddressEncountered
VLAN ID Invalid Configuration oriTrapVLANIDInvalidConfiguration
Auto Configuration Failure oriTrapAutoConfigFailure
CLI Configuration Execution Failure oriTrapBatchExecFailure
CLI Configuration Execution Start oriTrapBatchFileExecStart
CLI Configuration Execution End oriTrapBatchFileExecEnd