CP-SX1350(P5SX+)
Adjustment procedure 1
(when a color differential meter is used)
1.  First adjust [MID-L] tone [G:].
2.  Select adjustment point [No.2][G:].
  When the background is not [G] monochrome, 
press the [ENTER] key on the Remote control 
transmitter to change to solid [G] monochrome.
3.  Measure the illumination at adjustment points 
No. 2, No.3, No.10 and No.11.
  The values should be:
  No.2 = Y2 [lx] No.10 = Y10 [lx]
  No.3 = Y3 [lx] No.11 = Y11 [lx]
4.  No.2 and No.3 adjustment point have the 
average of Y2 and Y3.
  Y2 = ( Y2 + Y3 ) / 2 ± 3 [%]
  Y3 = ( Y2 + Y3 ) / 2 ± 3 [%]
5.  No.10 and No.11 adjustment point have the 
average of Y10 and Y11.
  Y10 = ( Y10 + Y11 ) / 2 ± 3 [%]
  Y11 = ( Y10 + Y11 ) / 2 ± 3 [%]
6.  Then adjust [MID-L] tone [R] and [B].
  When the background is [G] monochrome, 
press the [ENTER] key on the Remote control 
transmitter to change to solid white.
7.  Measure the color coordinates of adjustment 
point [No.1] and make a note of them.
  Assume that they are x = x1, y = y1.
  Note: When the CL-100 color and color 
difference meter is used, the [
](delta) 
mode is convenient. When adjustment 
point [No.1] color coordinate has been 
selected, set the slide switch on the side 
to [
](delta) while holding down the [F] 
button on the front panel. The 
measurement shown after this displays 
the deviation from measurement point 1.
8.  Measure the color coordinates of measurement 
point [No.2] and adjust [No.2][R:] and [B:] so 
that the coordinates are as follows.
  x = x1 ± 0.005 , y = y1 ± 0.010
9.  Similarly, measure adjustment points [No.3] to 
[No.17] and adjust their color coordinates 
starting in order from the small number points.
  This completes adjustments required for [MIN].
  Note: Since excessive correction may lead to a 
correction data overview during internal 
calculations, use the following values for 
reference.
    [No.2] to [No.5] ± 40 or less
    [No.6] to [No.9] ± 50 or less
    [No.10] to [No.13] ± 70 or less
    [No.14] to [No.17] ± 120 or less
10. Then adjust [MIN] tone [G] so that the 
adjustment data set two times as much as 
[MID-L] tone [G].
  This completes [G] color adjustments.
11. Then adjust [MIN] tone [R] and [B].
  Select [No.2] [B:] and press the [ENTER] key 
on the Remote control transmitter to change to 
solid white.
12. Measure the color coordinates of adjustment 
point [No.1] and make a note of them.
  Assume that they are x = x1, y = y1.
13. Now measure the color coordinates of 
measurement point [No.2] and adjust [No.2][R:] 
and [B:] so that the coordinates are as follows.
  x = x1 ± 0.005 , y = y1 ± 0.010 (Target)
  x = x1 ± 0.020 , y = y1 ± 0.040
14. Similarly, measure adjustment points [No.3] to 
[No.17] and adjust their color coordinates 
starting in order from the small number points.
  This completes [MIN] tone adjustments.
15. Now make similar adjustments for [MID-H] tone.
  (Adjust [MID-H] tone [G] so that the adjustment 
data set half as many as [MID-L] tone [G].)
16. Now make similar adjustments for [MAX] tone.
  (Adjust [MAX] tone [G] so that the adjustment 
data set half as many as [MID-L] tone [G].)