User's Manual

13
VIBCONNECT RF 11.2011
Safety
machinery.
Note
Risk of damage to equipment while housing is open!
Touching the electronic components on the mother board can lead
to electrostatic discharge, which can damage system components.
» If contact with such components cannot be excluded, wear an
earthing wristband.
Note
EMC
High-frequency radiation and electrostatic discharge (ESC) near
the sensors can lead to incorrect measurements.
» Do not install sensor cables in high-voltage cable ducts.
Note
Avoid potential loops when extending the antenna
If you need to extend the antenna from the housing to achieve
better reception, the antenna cable might cause a potential in the
sensor unit / bridge.
» Install the antenna cable so that potential differences are avoided.