Installation and Operation Guide
Table Of Contents
- Chapter 1: Introduction
 - 1.1 First steps
 - 1.2 Service addresses
 - 1.3 About this manual
 - Chapter 2: Safety
 - 2.1 Safety symbols
 - 2.2 Information for the system operator
 - 2.3 Information for operating personnel
 - 2.4 Intended use
 - 2.5 Residual risks and safety measures
 - Declaration of conformity
 - Certifications
 - Chapter 3: Technical data
 - Chapter 4: System description
 - 4.1 VIBCONNECT RF bridge
 - 4.2 VIBCONNECT RF sensor unit
 - 4.3 VIBCONNECT RF sensor
 - Chapter 5: Installation & commissioning
 - 5.1 Quick guide
 - 5.2 Configuration in OMNITREND
 - 5.3 Installation & commissioning of bridge
 - 5.4 Installation & commissioning of sensor unit
 - 5.5 Installation of sensors
 - 5.6 Configuration in OMNITREND (continued)
 - 5.7 Installing additional sensor unit
 - Chapter 6: Maintenance
 - 6.1 Cleaning
 - 6.2 System time correction
 - 6.3 Installation report
 - 6.4 Battery-powered sensor unit
 - 6.5 Update
 - 6.6 Warranty
 - 6.7 Spare parts and accessories
 - Chapter 7: Troubleshooting
 - Chapter 8: After use
 
17
VIBCONNECT RF 05.2012
Chapter 3: Technical data
VIBCONNECT RF Bridge – VIB 7.220, VIB 7.225
Radio transmission frequency band
  868 MHz (Europe, VIB 7.220) 
  916 MHz (America, VIB 7.220)
  2435 MHz (Worldwide, VIB 7.225)
Ethernet
  Baud rate: 10 / 100 Mbit/s
Memory
  256 MB
Capacity
  up to 50 sensor units
Power supply
  100 ... 240 VAC / 50-60 Hz
Operating temperature
  – 25 °C ... +60 °C
Relative humidity
  < 95 %, non-condensing
Housing
  Steel sheet, powder-coated
Protection class
  IP 66, NEMA 4
Weight
  approx. 1.8 kg
Dimensions (in mm) and labeling
Technical data
Name plate
Power supply label
(High voltage)
150
R8
110
170
176
211
333
95
Color coding, antenna:
•  Grey (868 / 915 MHz)
•  Purple (2435 MHz)