Installation and Operation Guide

Table Of Contents
37
VIBCONNECT RF 05.2012
Power cable
In order to connect the power cable conveniently, you need to
remove the PE terminal and the power supply as follows:
Loosen the center screw on the PE terminal, and pull it gently to
the left of the DIN rail.
Slide the power supply to the left so that it is not stuck in the
mounting flap screw when lifting it out.
Release the lock on the power supply with a suitable screwdriver:
Slide the screwdriver into the flap at the bottom of the power
supply and pull it down to release the lock. During this carefully
lift the power supply out of the DIN rail.
Note
The power supply is hardwired to the lower board. Do not tear or
damage the cables.
Feed the power cable through the
right gland.
Drag one of the enclosed ferrite
sleeves over the cable end.
Connect the power cable to the pow-
er supply and the PE terminal (see
also '5.3.6 Overview of connections
and interfaces', page 38).
Reinstall the power supply and the PE
terminal on the DIN rail.
Tighten the cable glands.
Remove PE terminal and
power supply.
L
N
PE
L
N
L
N
+
+
+
Mounting flap
screw
Network Power
Ferrite
sleeve
GN-YE
BN BU
Installation and commissioning