Installation and commissioning
5.3 Installation & commissioning of bridge
The bridge is contacted by OMNITREND through the network
(Ethernet). The bridge is addressed through the IP address of the
bridge. The factory-set address is:
192.168.63.01
If the address range of your network differs from the standard
range (e.g. 172. ... or 10. ... ), adjust the IP address of the bridge
accordingly before you install the bridge in the machine park.
5.3.1 Changing IP address of bridge
Note
The following steps must be carried out at a PC workstation that
features a free network port and is located near a power socket.
You also need an electric power cable to power the bridge. One
end of the cable must be equipped with a suitable plug, while
the other end must be prepared for connection to the bridge
(see “Connecting bridge”, page 34).
• Assign a static IP address that is within the range 192.168.... to
the PC.
• Connect the bridge to the network and then to the power source.
• Enter the IP address of the bridge in the browser (see above).
If no connection is established, change the connection settings
of your browser (proxy server, firewall, etc.).
• In the login dialog, enter the following:
User name: user3
Password: user3
The main menu of the bridge is displayed.
Change of
IP address of bridge