Hardware specifications
16bit MCU
256Kbit FRAM
2.4GHz BLE5
Rating
Usable temp.
-25 ~ 80
2 years
(based on manufacturing date)
Comm. cycle
(RF)
24 times / day
About 2 years
(based on 20 ℃, may vary depending on usage conditions)
Cycle time
range
0.2 ~ 300 sec / Press
55 x 46 x 26
2 ~ 300 sec / Injection
Please note that the service life of the battery may be shortened due to frequent operation or replacement.
Magnetic sensor recognition (SHOT)
15mm
60mm
SHOT IN
SHOT OUT
baseline
baseline
Carefully install the product and the magnet bracket as they will break when installed beyond the baseline.
LCD display
The LCD display changes each time the button is pressed, and returns to the cumulative shot display mode
within 30 seconds after the button is pressed.
No.
Display or setting
Display
example
Initial value
Remark
1
Cumulative shots display

0
-
2
Preset setting

-
-
3
ID display

1101XXX
Manufacturing number: 0-999
4
Setting mode

-
-
When using for the first time, please press the button once. (If not pressed, the LCD will not be displayed.)
Use the button only when setting.
QR code (13 digits)
Digits
1
2
2
2
1
2
3
Code
Powered
Type
Domestic /
International
Year of
production
Week of
production
Injection/
Press
Comm.
cycle
Manufacturing
Number
Display
P
CM / CG
20
01
I / P
01
001
Sensor recognition
Size (mm)
SHOT IN
< 15
SHOT OUT
> 60